A potential novel technique for measurement of pulp volume on periapical radiography: A pilot study

dc.authorid0000-0002-5863-5928en_US
dc.contributor.authorŞatır, Samed
dc.contributor.authorÖzel, Selale
dc.contributor.authorOrhan, Kaan
dc.date.accessioned2024-04-22T11:20:28Z
dc.date.available2024-04-22T11:20:28Z
dc.date.issued2024en_US
dc.departmentKMÜ, Ahmet Keleşoğlu Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.descriptionWOS:001180443100001 PubMed ID:38446557en_US
dc.description.abstractPulp volume can be assessed during dental treatment. Three-dimensional imaging techniques are not routinely used for this purpose because of high radiation doses. This study aimed to develop a novel method to measure pulp volume using periapical radiography. In this study, cone-beam computed tomography (CBCT) was used as a reference method. Periapical radiography and CBCTs obtained from the same patients (n = 32) were recorded. Pulp volume was determined by observing the density differences between the pulp and peripheral structures using ImageJ. A method of graph and volume calculation was developed for each tooth. The Shapiro-Wilk test and Mann-Whitney U test were used to show normality and non-normal distributions. The Bland-Altman plot was used to show the scattering of the mean versus difference values of the measurements of the two methods used to calculate the pulp volume. Normality was evaluated using the Shapiro-Wilk test. CBCT measurements are normally distributed (p = 0.307), while ImageJ is not normally distributed (p = 0.027). Therefore, the mean difference between the two groups was analyzed using the nonparametric Mann-Whitney U test. There was a statistically significant difference between the CBCT and ImageJ measurements (p = 0.01). According to Spearman's correlation analysis, the results obtained from the novel method were moderately correlated with those obtained from the reference method (r = 0.444). The results of this study indicated that a novel method-based Java software can be used to calculate pulp volume using low-dose radiation containing periapical radiography.en_US
dc.identifier.doi10.1002/kjm2.12814
dc.identifier.issn1607-551X
dc.identifier.issn2410-8650
dc.identifier.pmid38446557
dc.identifier.scopus2-s2.0-85187179451
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1002/kjm2.12814
dc.identifier.urihttps://hdl.handle.net/11492/8428
dc.identifier.wosWOS:001180443100001
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Sceince
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorŞatır, Samed
dc.language.isoen
dc.publisherWileyen_US
dc.relation.journalKaohsiung Journal of Medical Sciencesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCBCTen_US
dc.subjectImagrjen_US
dc.subjectPeriapical Radiographyen_US
dc.subjectPulp Volumeen_US
dc.titleA potential novel technique for measurement of pulp volume on periapical radiography: A pilot studyen_US
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Satır, Samed.pdf
Boyut:
1.59 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: