Photon and neutron shielding performance of boron phosphate glasses for diagnostic radiology facilities

dc.authorid0000-0003-3807-1587en_US
dc.contributor.authorTekin, H. O.
dc.contributor.authorAltunsoy Güçlü, E. E.
dc.contributor.authorKavaz, E.
dc.contributor.authorSayyed, M. I.
dc.contributor.authorAğar, Osman
dc.contributor.authorKamışlıoğlulu, M.
dc.date.accessioned2019-12-06T21:15:11Z
dc.date.available2019-12-06T21:15:11Z
dc.date.issued2019
dc.departmentKMÜ, Kamil Özdağ Fen Fakültesi, Fizik Bölümüen_US
dc.descriptionWOS:000460704700214en_US
dc.description.abstractThis study focuses on radiation shielding characteristics of Li2O, Al2O3 and ZnO-doped boron phosphate glasses containing PbO and Bi2O3. Mass attenuation coefficient (mu/rho) values of the glasses have been calculated using MCNPX code at various photon energies ranging from 60 to 120 keV and compared to those of XCOM software. The obtained results exhibited that MCNPX and XCOM are in good agreement at all energies. Some shielding parameters such as effective atomic number (Z(eff)), effective electron density (N-el), half value layer (HVL), mean free path (MFP) and Photon transmission factors (TF-photon) were determined using the obtained mass attenuation coefficients. Moreover, macroscopic effective removal cross sections (Sigma R) and neutron transmission factors (TF-neutron) for fast neutrons have been evaluated. To simulate the attenuation properties of investigated glasses in a diagnostic radiology operation facility (control room), each boron phosphate glass sample was placed in front of a mathematical human head phantom namely SNYDER. For the glasses under examination, average photon flux in the eight detection points, which were located in different points of SNYDER head phantom, was calculated. Among the studied glasses, BPM4 sample has showed superior photon and neutron radiation shielding effectiveness. It can be concluded that boron-doped glasses are superior shielding materials for both gamma ray and neutrons.en_US
dc.identifier.citationTekin, H. O., Altunsoy, E. E., Kavaz, E., Sayyed, M. I., Ağar, O., ... Kamışlıoğlu, M. (2019). Photon and neutron shielding performance of boron phosphate glasses for diagnostic radiology facilities. Results in Physics, 12, 1457-1464.
dc.identifier.doi10.1016/j.rinp.2019.01.060
dc.identifier.endpage1464en_US
dc.identifier.issn2211-3797
dc.identifier.scopus2-s2.0-85060686192
dc.identifier.scopusqualityQ1
dc.identifier.startpage1457en_US
dc.identifier.urihttps://dx.doi.org/10.1016/j.rinp.2019.01.060
dc.identifier.urihttps://hdl.handle.net/11492/2479
dc.identifier.volume12en_US
dc.identifier.wosWOS:000460704700214
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Sceince
dc.indekslendigikaynakScopus
dc.institutionauthorAğar, Osman
dc.language.isoen
dc.publisherElsevier Science Bven_US
dc.relation.journalResults in Physicsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBoron Phosphate Glassesen_US
dc.subjectMCNPXen_US
dc.subjectRadiation Protectionen_US
dc.subjectSNYDERen_US
dc.titlePhoton and neutron shielding performance of boron phosphate glasses for diagnostic radiology facilitiesen_US